1. Can I operate the SVP2xxx without a control unit?
2. I have an SVPxxxx and the trip latch is incorrectly handed.
3. How can I modify the circuitry of the SVP-S 2x in order, for example, to switch to permanent-release during the day?
4. How do I change the SVP 6xxx circuitry in order to engage or disengage the lever handle?
5. What does a triple flash sequence on the SVP control unit mean?
6. I am unable to actuate the lock via In1 (X2).
7. How is the control unit supplied with power?
8. The illuminated circle on the terminal is red, the yellow LEDs flash and an audible alarm is sounding.
9. The illuminated circle on the terminal is green and a slow-beat audible alarm is sounding.
10. The illuminated circle is red and the yellow LEDs flash without an audible alarm.
11. The input at the I/O module does not operate.
12. There is no door-open alarm – what is the reason for this?
13. I cannot get any connection to the door.

1. Can I operate the SVP2xxx without a control unit?
average appraisal: 0.4  count of votes: 9average appraisal: 0.4  count of votes: 9average appraisal: 0.4  count of votes: 9average appraisal: 0.4  count of votes: 9
appraisal of results

No, a control unit is mandatory for ensuring correct operability.

 

2. I have an SVPxxxx and the trip latch is incorrectly handed.
average appraisal: 0.3  count of votes: 8average appraisal: 0.3  count of votes: 8average appraisal: 0.3  count of votes: 8average appraisal: 0.3  count of votes: 8
appraisal of results

Use the Allen key provided in order to undo the grub screw located in the side of the lock case at the level of the trip latch, and then rotate the trip latch to the correct handing.

 

3. How can I modify the circuitry of the SVP-S 2x in order, for example, to switch to permanent-release during the day?
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

Terminals 23 and 28 on X2 must be closed via a floating contact. As long as the contact is closed, the lock remains disengaged.

 

4. How do I change the SVP 6xxx circuitry in order to engage or disengage the lever handle?
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

The black wire is connected to ground, the white to 12V DC and the red is connected via a floating contact to black (ground).

 

5. What does a triple flash sequence on the SVP control unit mean?
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

Either the door contact is not closed with the SVP in its locked state, or the gap between the forend and the strike plate is more than 5.5 mm, or the feedback signal via conductor 49 is not functioning.

 

6. I am unable to actuate the lock via In1 (X2).
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
 

The address must be set to LON mode (dip switch 1 at ON). Set to this position with the system switched off.

 
appraisal of results

7. How is the control unit supplied with power?
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

Either via terminals 1 and 3 with 24VDC, or via X1 with 12VDC.

 

8. The illuminated circle on the terminal is red, the yellow LEDs flash and an audible alarm is sounding.
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

The door contact is not operating properly or none is provided and terminals 3 and 18 are not jumpered.

 

9. The illuminated circle on the terminal is green and a slow-beat audible alarm is sounding.
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

a) The locking time has expired and the door is still open or is otherwise unable to lock. Or b) The lock is active but the red feedback signal wire (terminal 4) has been interrupted => check wire

 

10. The illuminated circle is red and the yellow LEDs flash without an audible alarm.
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

A DCW component has been disabled or an address has been changed. Disconnect the power, hold the red pushbutton down, reinstate the power and release the pushbutton.

 

11. The input at the I/O module does not operate.
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

The inputs must be live. The opto-couplers operate at a voltage of 5-30 V DC.

 

12. There is no door-open alarm – what is the reason for this?
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

The TL-S5 does not offer this function.

 

13. I cannot get any connection to the door.
average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7average appraisal: 0  count of votes: 7
appraisal of results

RS232: After programming-in the door during the initialisation phase, click on the button "(Neue Türadresse) New Door Address". Check the jumpers on the PC adapter. LON: In the PC communications window "(Aktion/Datenbank trennen) Separate Action/Database", change settings to PC card or LON gateway. After programming-in the door during the initialisation phase, click on the button "(Neue LON-Adresse) New LON Address".